Sign In | Join Free | My infospaceinc.com
China Golden Smile Dental Lab logo
Golden Smile Dental Lab
Verified Supplier

1 Years

Home > Precision Attachment >

Bridge with Ball Cap Attachments & Metal Framework

Golden Smile Dental Lab
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Bridge with Ball Cap Attachments & Metal Framework

Certification : ISO/CE/FDA

Place of origin : Shenzhen ,China

Price : Negotiable

Maintenance : Brush with non-abrasive paste

Place of Origin : Shenzhen, China

Aesthetics : Clasp-free / Hidden Retention Design

Material : Noble Metal PFM / Co-Cr Alloy Optional

Supply Ability : 300 Technicians

Function : Fixed-Removable Hybrid Dental Restoration

Brand Name : GS

Retention : Secure Snap-Fit Ball Interlocking System

MOQ : Negotiable

Stability : Superior Lateral & Vertical Resistance

Payment Terms : Paypal or T/T

Biocompatibility : Medical Grade , Corrosion Resistant / Tissue Friendly

Packaging Details : Plastic bags and box

User Comfort : Uniform Occlusal Force, Low Intraoral Bulk

Structure : PFM Crown + Male&Female Ball Attachment

Contact Now

Product Overview

This is a premium fixed-removable combined dental restoration, composed of a fixed bridge with male ball attachments and a removable cast metal framework fitted with female cap inserts. It relies on concealed ball-cap interlocking for retention, avoiding visible clasps, delivering both stable chewing performance and easy cleaning for complex partially edentulous cases.

Product Advantages
  • Superior Aesthetics: No exposed metal clasps. The retention mechanism is concealed internally for a natural smile, ideal for anterior restorations.
  • Stable Retention & High Masticatory Efficiency: Mechanical locking of ball-cap attachments prevents wobbling or lifting during chewing, with well-distributed occlusal force and far better chewing performance than ordinary acrylic dentures.
  • Abutment Protection: Vertical insertion and removal generate minimal lateral torque on abutments, lowering the risk of loosening and damage. Gaps around the ball facilitate cleaning and reduce secondary caries.
  • Thin & Comfortable Framework: High-strength cast metal allows slim framework design, less bulk and fewer foreign-body sensations compared to full acrylic bases.
  • Adjustable Retention & Easy Repair: Retention force can be adjusted by replacing nylon caps of different retention grades. Worn caps can be replaced separately without remaking the whole prosthesis, controlling long-term maintenance cost.
  • Excellent Biocompatibility: Made of medical-grade cobalt-chromium alloy or pure titanium, corrosion-resistant with low oral allergy risk.
Product Specifications

Customized digitally via CAD/CAM according to individual patient impressions.

Framework Material Options Cobalt-chromium alloy, pure titanium
Ball Cap Components Standard ball diameters 1.8 mm (Micro), 2.5 mm (Standard); interchangeable nylon caps with low / medium / high retention (color-coded)
Artificial Teeth Multi-layer acrylic teeth or zirconia teeth, shade selection following Vita shade guide
Arch Custom for maxilla or mandible; framework hollowing and reinforcement ribs designed based on Kennedy classification of edentulous spans
Fabrication Traditional precision casting / 3D laser sintering, fitting tolerance ≤0.05 mm
Application
  1. For patients with a small number of healthy remaining abutments and multiple missing teeth, who refuse full dentures and cannot receive implant treatment.
  2. Anterior edentulous cases with high aesthetic demand and rejection of visible clasps.
  3. Complex partially edentulous restorations requiring fixed-removable combined design to distribute occlusal load.
  4. Also compatible with implant abutment version: implant-supported fixed bridge paired with ball-cap metal framework overdenture.

Daily Cleaning
  1. Remove and rinse the prosthesis right after meals. Clean the framework, teeth and gaps of ball caps gently with a soft denture brush. Never use hard brushes or wire brushes which scratch metal and attachments.
  2. Clean the fixed bridge and ball heads on abutments with interdental brushes to remove food debris around the ball base, preventing plaque accumulation and periodontal issues.
  3. Take out the denture every night and soak it in professional denture cleanser. Avoid undiluted bleach which corrodes metal and accelerates aging of nylon caps. Rinse thoroughly with clean water before storage.
Periodic Inspection & Part Replacement
  1. Nylon retention caps are consumables. Check every 6–12 months. Replace caps when retention weakens, sticking or wear occurs; no need to remake the metal framework.
  2. Visit the dental clinic for review every 6 months, to check abutment periodontal health, framework deformation, ball wear and occlusal condition.
  3. If scratches or rough spots appear on polished metal surfaces, send back for repolishing to avoid plaque retention.
Prohibited Operations
  • Do not chew hard food (bones, hard nut shells) with the denture, to prevent framework distortion or attachment fracture.
  • Never store it dry when not in use; keep it moist to avoid cracking of gingival acrylic.
  • Do not grind or bend the metal framework by yourself. Deformation will cause abnormal force on abutments and poor seating.

Product Tags:

Bridge with Ball Cap Attachments

      

Metal Framework Bridge Attachment

      

Precision Bridge Ball Cap Attachment

      
Quality Bridge with Ball Cap Attachments & Metal Framework for sale

Bridge with Ball Cap Attachments & Metal Framework Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Golden Smile Dental Lab
*Subject:
*Message:
Characters Remaining: (0/3000)